DSC Power 832 - PC5501Z Keypad - Zone 1 Question Surebet 06-05-2006
Posted by Surebet on June 5, 2006, 10:59 pm
If you were  Registered and logged in, you could reply and use other advanced thread options
I've read the manual and have a question. Is the wiring for zone 1
different than the other zones? All of my other zones work fine
except for zone 1. I know the contact is good and I have even
replaced it on the panel with a jumper between ZN1 and COM and yet the
system still sees zone 1 as open. Any suggestions?

-Russ

Posted by Tommy on June 5, 2006, 10:45 pm
If you were  Registered and logged in, you could reply and use other advanced thread options
Check your programming to see if you have zone one assigned to the
keypad.
--



Surebet wrote:

> I've read the manual and have a question. Is the wiring for zone 1
> different than the other zones? All of my other zones work fine
> except for zone 1. I know the contact is good and I have even
> replaced it on the panel with a jumper between ZN1 and COM and yet the
> system still sees zone 1 as open. Any suggestions?
>
> -Russ

--
Posted via a free Usenet account from http://www.teranews.com


Posted by J Barnes on June 5, 2006, 11:44 pm
If you were  Registered and logged in, you could reply and use other advanced thread options
A jumper or a Resistor? Zone 1 works the same as the other zones. Try
putting the resistor across zone one but make sure to disconnect the actual
zone wires from it. This should narrow it down.

James


> I've read the manual and have a question. Is the wiring for zone 1
> different than the other zones? All of my other zones work fine
> except for zone 1. I know the contact is good and I have even
> replaced it on the panel with a jumper between ZN1 and COM and yet the
> system still sees zone 1 as open. Any suggestions?
>
> -Russ



Posted by Bob La Londe on June 6, 2006, 10:22 am
If you were  Registered and logged in, you could reply and use other advanced thread options
Zone programmed for NO EOLR maybe?


> I've read the manual and have a question. Is the wiring for zone 1
> different than the other zones? All of my other zones work fine
> except for zone 1. I know the contact is good and I have even
> replaced it on the panel with a jumper between ZN1 and COM and yet the
> system still sees zone 1 as open. Any suggestions?
>
> -Russ



--
Posted via a free Usenet account from http://www.teranews.com


Posted by Surebet on June 6, 2006, 8:43 pm
If you were  Registered and logged in, you could reply and use other advanced thread options
Figured it out. Actually it was because the keypad was setup to be
used as a zone as well. I'm learning a great deal in this process and
the people and messages in this group are helping. Thanks everyone!

Similar ThreadsPosted
Ademco 6150 Keypad Zone October 20, 2005, 12:54 am
RE: Ademco 6150 Keypad Zone October 20, 2005, 2:26 am
Optima 2 plus - flashing Red Power LED on Keypad ? April 16, 2006, 6:52 am
problem with dsc 1616 power keypad October 22, 2007, 12:02 am
Ademco Keypad not working after extended power outage January 14, 2007, 2:20 pm
Question about Napco 8-zone expander October 22, 2005, 4:47 pm
question about what defines an alarm "zone" February 27, 2006, 6:28 pm
Concord Wireless Zone Question July 12, 2006, 7:50 pm
Gemini P816 - keypad question November 15, 2006, 1:45 pm
Re: '98 XJ Power Steering question April 22, 2007, 1:53 am

The site map in XML format XML site map

Contact Us | Privacy Policy