Posted by Michael on January 15, 2007, 8:28 am
If you were Registered and logged in, you could reply and use other advanced thread options Global Address is 31. That should be what's required for the Vista
20SE.
On Sun, 14 Jan 2007 14:05:57 -0600, "Stanley Barthfarkle"
>First, you need to determine the keypad's address. Press the "1" and "3"
>keys simultaneously, and a 2 digit number will appear. This is the keypad
>address. To change this, enter the desired 2 digit address, then press "*".
>
>I don't recall what the global keyoad address should be on that system, but
>I would try 31, then 00, then 08.
>
>Someone should be along shortly to correct me on which address to use. :-)
>
>
>
>>I have a Ademco Vista 20SE system with two keypads (M6673). Following a
>> winter power outage of 4 days, one of the two keypads doesn't work,
>> however the system works fine with the other keypad.
>>
>> I verified that the keypad is the issue by switching the two keypads
>> (dismount from wall and swap) so I am confident that all wiring is
>> fine.
>>
>> On power up, the bad keypad turns on all LCD indications, lights both
>> the LEDS (red & Green) and then blanks the LCD display. The keypad
>> responds by beeping on the first 4 or 6 keypresses, but after that
>> nothing.
>>
>> Is this a programming issue? Visual inspection of the board shows no
>> issues.
>>
>> Any ideas how to get this back online or is this keypad done for good?
>>
>> Thanks,
>> --Randy
>
|