-----BEGIN PGP SIGNED MESSAGE-----
Hash: SHA1

SUPPORT COMMUNICATION - SECURITY BULLETIN

Document ID: c01123426
Version: 3

HPSBUX02251 SSRT071449 rev.3 - HP-UX Running BIND, Remote DNS Cache Poisoning

NOTICE: The information in this Security Bulletin should be acted upon as soon
as possible.

Release Date: 2007-08-01
Last Updated: 2007-11-26

Potential Security Impact: Remote DNS cache poisoning

Source: Hewlett-Packard Company, HP Software Security Response Team

VULNERABILITY SUMMARY
A potential vulnerability has been identified with HP-UX running BIND. The
vulnerability could be exploited remotely to cause DNS cache poisoning.

References: CVE-2007-2926

SUPPORTED SOFTWARE VERSIONS*: ONLY impacted versions are listed.
HP-UX B.11.11, B.11.23, B.11.31 running BIND v9.2.0 or BIND v9.3.2

BACKGROUND

To determine if a system has an affected version, search the output of "swlist
-a revision -l fileset" for an affected fileset. Then determine if the
recommended action has been taken.

AFFECTED VERSIONS

For BIND v9.2.0

HP-UX B.11.11
=============
BINDv920.INETSVCS-BIND
action: install BIND920_v10.depot

HP-UX B.11.23
=============
InternetSrvcs.INETSVCS2-RUN
action: install PHNE_36973 or subsequent

For BIND v9.3.2

HP-UX B.11.11
=============
BindUpgrade.BIND-UPGRADE
action: install revision C.9.3.2.2.0 or subsequent
URL:
http://h20293.www2.hp.com/portal/swdepot/displayProductInfo.do?productNumber=BIND

HP-UX B.11.23
=============
BindUpgrade.BIND2-UPGRADE
action: install revision C.9.3.2.2.0 or subsequent
URL:
http://h20293.www2.hp.com/portal/swdepot/displayProductInfo.do?productNumber=BIND

HP-UX B.11.31
=============
NameService.BIND-RUN
- ->action: install revision C.9.3.2.1.0 or subsequent
URL:
http://h20293.www2.hp.com/portal/swdepot/displayProductInfo.do?productNumber=BIND

END AFFECTED VERSIONS



RESOLUTION
HP has provided the following software updates and patches to resolve the
vulnerability.

The patch is available from http://itrc.hp.com

The updates are available from
http://h20293.www2.hp.com/portal/swdepot/displayProductInfo.do?productNumber=BIND

BIND v9.2.0
HP-UX B.11.11
contact HP Support to receive BIND920_v10.depot or upgrade to BIND v9.3.2
revision C.9.3.2.2.0 or subsequent

BIND v9.2.0
HP-UX B.11.23
install PHNE_36973 or subsequent

BIND v9.3.2
HP-UX B.11.11
install revision C.9.3.2.2.0 or subsequent

BIND v9.3.2
HP-UX B.11.23
install revision C.9.3.2.2.0 or subsequent

- ->BIND v9.3.2
HP-UX B.11.31
install revision C.9.3.2.1.0 or subsequent



MANUAL ACTIONS: Yes - NonUpdate
BIND v9.2.0 HP-UX B.11.11 - contact HP Support or upgrade to BIND v9.3.2

PRODUCT SPECIFIC INFORMATION

HP-UX Software Assistant: HP-UX Software Assistant is an enhanced application
that replaces HP-UX Security Patch Check. It analyzes all HP-issued Security
Bulletins and lists recommended actions that may apply to a specific HP-UX
system. It can also download patches and create a depot automatically. For more
information see: https://www.hp.com/go/swa

HISTORY
Version: 1 (rev.1) - 1 August 2007 Initial release
Version: 2 (rev.2) - 10 September 2007 patch and updates available
Version: 3 (rev.3) - 26 November 2007 B.11.31 update available

Third Party Security Patches: Third party security patches which are to be
installed on systems running HP software products should be applied in
accordance with the customer's patch management policy.



Support: For further information, contact normal HP Services support channel.

Report: To report a potential security vulnerability with any HP supported
product, send Email to: security-alert@hp.com
It is strongly recommended that security related information being communicated
to HP be encrypted using PGP, especially exploit information.
To get the security-alert PGP key, please send an e-mail message as follows:
To: security-alert@hp.com
Subject: get key

Subscribe: To initiate a subscription to receive future HP Security Bulletins
via Email:
http://h30046.www3.hp.com/driverAlertProfile.php?regioncode=NA&langcode=USENG&jumpid=in_SC-GEN__driverITRC&topiccode=ITRC
On the web page: ITRC security bulletins and patch sign-up
Under Step1: your ITRC security bulletins and patches
- check ALL categories for which alerts are required and continue.
Under Step2: your ITRC operating systems
- verify your operating system selections are checked and save.


To update an existing subscription: http://h30046.www3.hp.com/subSignIn.php
Log in on the web page: Subscriber's choice for Business: sign-in.
On the web page: Subscriber's Choice: your profile summary - use Edit Profile to
update appropriate sections.


To review previously published Security Bulletins visit:
http://www.itrc.hp.com/service/cki/secBullArchive.do


* The Software Product Category that this Security Bulletin relates to is
represented by the 5th and 6th characters of the Bulletin number in the title:

GN = HP General SW
MA = HP Management Agents
MI = Misc. 3rd Party SW
MP = HP MPE/iX
NS = HP NonStop Servers
OV = HP OpenVMS
PI = HP Printing & Imaging
ST = HP Storage SW
TL = HP Trusted Linux
TU = HP Tru64 UNIX
UX = HP-UX
VV = HP VirtualVault


System management and security procedures must be reviewed frequently to
maintain system integrity. HP is continually reviewing and enhancing the
security features of software products to provide customers with current secure
solutions.


"HP is broadly distributing this Security Bulletin in order to bring to the
attention of users of the affected HP products the important security
information contained in this Bulletin. HP recommends that all users determine
the applicability of this information to their individual situations and take
appropriate action. HP does not warrant that this information is necessarily
accurate or complete for all user situations and, consequently, HP will not be
responsible for any damages resulting from user's use or disregard of the
information provided in this Bulletin. To the extent permitted by law, HP
disclaims all warranties, either express or implied, including the warranties of
merchantability and fitness for a particular purpose, title and
non-infringement."

©Copyright 2007 Hewlett-Packard Development Company, L.P.

Hewlett-Packard Company shall not be liable for technical or editorial errors or
omissions contained herein. The information provided is provided "as is" without
warranty of any kind. To the extent permitted by law, neither HP or its
affiliates, subcontractors or suppliers will be liable for incidental, special
or consequential damages including downtime cost; lost profits; damages relating
to the procurement of substitute products or services; or damages for loss of
data, or software restoration. The information in this document is subject to
change without notice. Hewlett-Packard Company and the names of Hewlett-Packard
products referenced herein are trademarks of Hewlett-Packard Company in the
United States and other countries. Other product and company names mentioned
herein may be trademarks of their respective owners.
-----BEGIN PGP SIGNATURE-----
Version: PGP 8.1

iQA/AwUBR0rPzOAfOvwtKn1ZEQLWNwCggTba5J17m1eI5fD2MPnGyqFkYy8AoMDz
rvWcGWB7sMC6nOCOHRFUUukk
=UY9z
-----END PGP SIGNATURE-----

--
Yours truly,
HP S/W Security Team
WTEC Cupertino, California


Return-Path: secure@cup.hp.com
Reply-to: security-alert@hp.com

Similar ThreadsPosted
HPSBUX02251 SSRT071449 rev.1 - HP-UX Running BIND, Remote DNS Cache Poisoning August 6, 2007, 10:24 am
HPSBUX02251 SSRT071449 rev.2 - HP-UX Running BIND, Remote DNS Cache Poisoning September 20, 2007, 9:38 am
HPSBUX02289 SSRT071461 rev.1 - HP-UX Running BIND 8, Remote DNS Cache Poisoning November 20, 2007, 9:02 am
HPSBUX02351 SSRT080058 rev.1 - HP-UX Running BIND, Remote DNS Cache Poisoning July 16, 2008, 10:22 pm
HPSBUX02351 SSRT080058 rev.2 - HP-UX Running BIND, Remote DNS Cache Poisoning July 19, 2008, 7:30 am
HPSBUX02351 SSRT080058 rev.3 - HP-UX Running BIND, Remote DNS Cache Poisoning August 6, 2008, 4:46 pm
HPSBUX02351 SSRT080058 rev.4 - HP-UX Running BIND, Remote DNS Cache Poisoning August 9, 2008, 6:21 am
HPSBUX02219 SSRT061273 rev.1 - HP-UX Running BIND, Remote Denial of Service (DoS) June 12, 2007, 2:41 pm
SSRT4861 rev.0 - HP-UX BIND 9.2.0 remote Denial of Service (DoS) February 9, 2005, 1:34 pm
SSRT4861 rev.1 - HP-UX BIND 9.2.0 remote Denial of Service (DoS) March 2, 2005, 12:12 pm

The site map in XML format XML site map

Contact Us | Privacy Policy