programming an Ademco Vista

programming an Ademco Vista

Secure Home | Search | About
 CCTV, Alarms and other Physical Security    Post an article   get this group's latest topics as an RSS feed add this group's latest topics to your My MSN content add this group's latest topics to your My Yahoo content add this group's latest topics to your Google content
Subject Author Date
programming an Ademco Vista rickm 04-22-2008
Posted by on April 22, 2008, 10:49 pm
If you were  Registered and logged in, you could reply and use other advanced thread options
Has anyone programmed an Ademco Vista 20P? Whats a typical entry for
*182:

1) door switches
2) IR motion

thanks

Posted by Crash Gordon on April 23, 2008, 1:08 am
If you were  Registered and logged in, you could reply and use other advanced thread options
I hardly ever use customizable zone types.
Is there a reason you don't want to use normal zone types?

01 Entry/Exit #1 - delayed doors
03 Perimeter - instant doors/windows
04 Interior Follower - interior device (pir) that follows entry delay if
delay zones are faulted first... but instant in other cases




--
**Crash Gordon**







> Has anyone programmed an Ademco Vista 20P? Whats a typical entry for
> *182:
>
> 1) door switches
> 2) IR motion
>
> thanks



Posted by on April 23, 2008, 6:33 pm
If you were  Registered and logged in, you could reply and use other advanced thread options
wrote:
> I hardly ever use customizable zone types.
> Is there a reason you don't want to use normal zone types?
>
> 01 Entry/Exit #1 - delayed doors
> 03 Perimeter - instant doors/windows
> 04 Interior Follower - interior device (pir) that follows entry delay if
> delay zones are faulted first... but instant in other cases
>
> --
> **Crash Gordon**
>
>
>
> > Has anyone programmed an Ademco Vista 20P? Whats a typical entry for
> > *182:
>
> > 1) door switches
> > 2) IR motion
>
> > thanks

Im after just a vanilla setup, the manual implies that *182 is
required so thats what I was trying to get working.
Sounds like that is not right so Im open. Is *56 the right field?

Posted by Crash Gordon on April 23, 2008, 11:53 pm
If you were  Registered and logged in, you could reply and use other advanced thread options
*182 is for custom zones
just use *56 area and the zone types I gave or any of the standard ones on
page 12

--
**Crash Gordon**







> wrote:
>> I hardly ever use customizable zone types.
>> Is there a reason you don't want to use normal zone types?
>>
>> 01 Entry/Exit #1 - delayed doors
>> 03 Perimeter - instant doors/windows
>> 04 Interior Follower - interior device (pir) that follows entry delay if
>> delay zones are faulted first... but instant in other cases
>>
>> --
>> **Crash Gordon**
>>
>>
>>
>> > Has anyone programmed an Ademco Vista 20P? Whats a typical entry for
>> > *182:
>>
>> > 1) door switches
>> > 2) IR motion
>>
>> > thanks
>
> Im after just a vanilla setup, the manual implies that *182 is
> required so thats what I was trying to get working.
> Sounds like that is not right so Im open. Is *56 the right field?



Posted by on April 24, 2008, 4:36 pm
If you were  Registered and logged in, you could reply and use other advanced thread options
wrote:
> *182 is for custom zones
> just use *56 area and the zone types I gave or any of the standard ones on
> page 12
>
> --
> **Crash Gordon**
>
>
>
> > wrote:
> >> I hardly ever use customizable zone types.
> >> Is there a reason you don't want to use normal zone types?
>
> >> 01 Entry/Exit #1 - delayed doors
> >> 03 Perimeter - instant doors/windows
> >> 04 Interior Follower - interior device (pir) that follows entry delay if
> >> delay zones are faulted first... but instant in other cases
>
> >> --
> >> **Crash Gordon**
>
>
>
> >> > Has anyone programmed an Ademco Vista 20P? Whats a typical entry for
> >> > *182:
>
> >> > 1) door switches
> >> > 2) IR motion
>
> >> > thanks
>
> > Im after just a vanilla setup, the manual implies that *182 is
> > required so thats what I was trying to get working.
> > Sounds like that is not right so Im open. Is *56 the right field?

after *97 and *56, the Vista finally came up and showed some life.
testing is next

Thanks!!!

Similar ThreadsPosted
Ademco Vista Programming December 3, 2006, 6:27 pm
Ademco Vista 20 X10 programming question November 29, 2007, 6:30 pm
Need advice on programming Ademco 5804 key transmitter for the Vista 15 panel October 17, 2006, 7:12 pm
Ademco Vista 250BP Programming to Report Open / Close Events May 30, 2006, 5:44 pm
Re: Vista 20P Zone Descriptor Programming August 11, 2007, 8:46 pm
Re: Vista 20P Zone Descriptor Programming August 11, 2007, 9:36 pm
Ademco Vector 3000 converting to Ademco Vista 128BP June 2, 2008, 9:07 pm
*Complete* list of Vista 10SE programming codes? September 15, 2005, 5:32 am
Ademco programming June 5, 2005, 7:10 pm
Ademco Lynx X10 programming Question March 21, 2007, 10:19 pm

The site map in XML format XML site map