online DMP dealers?

online DMP dealers?

Secure Home | Search | About
 CCTV, Alarms and other Physical Security    Post an article   get this group's latest topics as an RSS feed add this group's latest topics to your My MSN content add this group's latest topics to your My Yahoo content add this group's latest topics to your Google content
Subject Author Date
online DMP dealers? blueman 02-07-2007
Posted by Crash Gordon on February 8, 2007, 9:44 am
If you were  Registered and logged in, you could reply and use other advanced thread options
you the brownstone nyc guy?

you have a 485 in a house?

ok only 4 keypads but what else...what other devices are using addresses or
are you running expanders on the LPX bus??

the 200 supports 8 device addresses so if you're using 4 for your kpds and
you have say 4 x 714's or 1 x 16 zone zone expander then your
finished...unless you know some tricks.



| > Do you know if you even can add a keypad to your system? There's some
| > programming to be done and there are limitations on how many keypad
| > addresses and device addresses are being used with what keypad.
| >
| > What panel?
| > How many keypads now?
| > How many and what device addresses are currently in use?
| >
| > Depending on your answers, you may not even be able to add one.
|
| I have a DMP XR200-485 panel which can support up to 16 keypads though
| I currently only have 4 installed. I know how to program the
| keypads...
|
| Thanks



Posted by blueman on February 8, 2007, 6:36 pm
If you were  Registered and logged in, you could reply and use other advanced thread options
> you the brownstone nyc guy?
>
> you have a 485 in a house?
>
> ok only 4 keypads but what else...what other devices are using addresses or
> are you running expanders on the LPX bus??
>
> the 200 supports 8 device addresses so if you're using 4 for your kpds and
> you have say 4 x 714's or 1 x 16 zone zone expander then your
> finished...unless you know some tricks.
>
>
>
> | > Do you know if you even can add a keypad to your system? There's some
> | > programming to be done and there are limitations on how many keypad
> | > addresses and device addresses are being used with what keypad.
> | >
> | > What panel?
> | > How many keypads now?
> | > How many and what device addresses are currently in use?
> | >
> | > Depending on your answers, you may not even be able to add one.
> |
> | I have a DMP XR200-485 panel which can support up to 16 keypads though
> | I currently only have 4 installed. I know how to program the
> | keypads...
> |
> | Thanks

I have 3 16-zone zone expanders plus each keypad of mine provides an
additional 4 zones. So technically I have:
8 zones (XR200-485 panel)
48 zones (3 expanders)
16 zones (4 keypads)
-------------------------
72 zones

Of those, I currently have 51 zones in use which give me 21 more
available.

I believe that the keypads and the zone expanders are on the LX bus so
they don't use up a zone.

Posted by West Alarm on February 8, 2007, 6:47 pm
If you were  Registered and logged in, you could reply and use other advanced thread options

>> you the brownstone nyc guy?
>>
>> you have a 485 in a house?
>>
>> ok only 4 keypads but what else...what other devices are using addresses or
>> are you running expanders on the LPX bus??
>>
>> the 200 supports 8 device addresses so if you're using 4 for your kpds and
>> you have say 4 x 714's or 1 x 16 zone zone expander then your
>> finished...unless you know some tricks.
>>
>>
>>
>> | > Do you know if you even can add a keypad to your system? There's some
>> | > programming to be done and there are limitations on how many keypad
>> | > addresses and device addresses are being used with what keypad.
>> | >
>> | > What panel?
>> | > How many keypads now?
>> | > How many and what device addresses are currently in use?
>> | >
>> | > Depending on your answers, you may not even be able to add one.
>> |
>> | I have a DMP XR200-485 panel which can support up to 16 keypads though
>> | I currently only have 4 installed. I know how to program the
>> | keypads...
>> |
>> | Thanks
>
>I have 3 16-zone zone expanders plus each keypad of mine provides an
>additional 4 zones. So technically I have:
> 8 zones (XR200-485 panel)
> 48 zones (3 expanders)
> 16 zones (4 keypads)
> -------------------------
> 72 zones
>
>Of those, I currently have 51 zones in use which give me 21 more
>available.
>
>I believe that the keypads and the zone expanders are on the LX bus so
>they don't use up a zone.


It's obvious that you know your system. Perhaps if you post a working
email address one of the DMP dealers reading your plight will offer to
sell you the keypad.


Posted by blueman on February 8, 2007, 9:59 pm
If you were  Registered and logged in, you could reply and use other advanced thread options
>
> >> you the brownstone nyc guy?
> >>
> >> you have a 485 in a house?
> >>
> >> ok only 4 keypads but what else...what other devices are using addresses or
> >> are you running expanders on the LPX bus??
> >>
> >> the 200 supports 8 device addresses so if you're using 4 for your kpds and
> >> you have say 4 x 714's or 1 x 16 zone zone expander then your
> >> finished...unless you know some tricks.
> >>
> >>
> >>
> >> | > Do you know if you even can add a keypad to your system? There's some
> >> | > programming to be done and there are limitations on how many keypad
> >> | > addresses and device addresses are being used with what keypad.
> >> | >
> >> | > What panel?
> >> | > How many keypads now?
> >> | > How many and what device addresses are currently in use?
> >> | >
> >> | > Depending on your answers, you may not even be able to add one.
> >> |
> >> | I have a DMP XR200-485 panel which can support up to 16 keypads though
> >> | I currently only have 4 installed. I know how to program the
> >> | keypads...
> >> |
> >> | Thanks
> >
> >I have 3 16-zone zone expanders plus each keypad of mine provides an
> >additional 4 zones. So technically I have:
> > 8 zones (XR200-485 panel)
> > 48 zones (3 expanders)
> > 16 zones (4 keypads)
> > -------------------------
> > 72 zones
> >
> >Of those, I currently have 51 zones in use which give me 21 more
> >available.
> >
> >I believe that the keypads and the zone expanders are on the LX bus so
> >they don't use up a zone.
>
>
> It's obvious that you know your system. Perhaps if you post a working
> email address one of the DMP dealers reading your plight will offer to
> sell you the keypad.

Thanks -- you guys have all been real gentlemen and I really respect
the service you provide. Unlike some of the other "pro" USENET newsgroups,
you all seem to be genuinely interested in doing what is right even if
some of you vary in your opinons of diy.

I also never hesitate to recommend the installer and monitoring company
that we use. However, as I have mentioned several times, personally, I
tend to need less hand holding than the average while getting pleasure
from pushing the limits of my system myself.

I also try to "give back" to the installer and their techs. For
example, I showed them how they could speed up their annual testing
by using the ICOM interface to print out the event history rather than
trying to read things sequentially from the keyboard or having to go
back to the CO for the event log.

My next step is to install some environmental sensors (water,
temperature) and potentially to "experiment" with the output
capabilities of the XR200-485. Of course, I will be "careful" and know
that I bear the risk of any accidental damage, etc...



Posted by Western Alarm on February 8, 2007, 10:35 pm
If you were  Registered and logged in, you could reply and use other advanced thread options
blueman inspired greatness with:

>
>Thanks -- you guys have all been real gentlemen and I really respect
>the service you provide. Unlike some of the other "pro" USENET newsgroups,
>you all seem to be genuinely interested in doing what is right even if
>some of you vary in your opinons of diy.


This NG is not really DIY 'friendly', but exceptions are made for
someone like you who knows the deal. There is a certain 'fish' that
would like DIY'ers to think pros are not friendly because of greed or
fear of losing some market share, that is not true. Most pros have
issue with DIY'ers because they don't do homework and expect pros to
answer questions in this NG, when the selling dealer should be
providing support. When 'we' need support we go to the manufacturer
or the wholesaler, something the DIY'er has no access to. A certain
criminal in this NG relys on the professional for knowledge, yet
denigrates him for getting a fair profit installing it.

I wish I could sell you the KP but I am not a DMP dealer. I know some
in this NG (and they have replied to you), but it will be up to them
to initiate contact.


Similar ThreadsPosted
Any Radionics dealers? April 11, 2006, 7:42 pm
Attention W.Pa. Alarm Dealers December 31, 2005, 9:09 am
DEALERS USING TELA-LINK... January 9, 2008, 6:11 pm
Danger - Independent Alarm Dealers November 20, 2005, 6:56 pm
ADT Hates It's Own Independent Dealers! Proof! November 21, 2005, 8:21 pm
Best place to buy parts for those of us who don't have a dealers license ? January 19, 2006, 11:09 pm