Posted by Russell Brill on May 9, 2008, 9:52 pm
If you were Registered and logged in, you could reply and use other advanced thread options
> Rich wrote:
>>> Rich wrote:
>>>> How do I clear a Fail to com remotely?
>>>>
>>>> Caddx NX8
>>> send a test signal
>> Where
>
> the place where test signals go.
>
Every time I read this board it puts a smile on my face... ha ha ha
>
>
>>What
>
>
> any communication with the cs will clear the FTC. easiest remotely would
> be to do as alarman said and send signal on download. after you turn that
> on in programming. if you use daily tests it will clear itself in 1 day
> or less.
>
>
>
>>
>> I ran a diagnostics and received an OK
>
> the question is why did you get a FTC and what was the event caused it? I
> have had to change test times on some systems to stop ftcs caused by the
> test signal.
>
> another good way to clear FTC's is to turn on manual test to send a test
> signal to the central station for the end users. then they can do manual
> test that will also send cs test by pressing [*4]. you can also prog
> manual test to do a battery test and siren test at the same time as the cs
> test signal. A nice feature for the user to ensure that battery, siren
> and comm is wOrKing.
|